Aspen Standard Peristaltic Condensate Pump Fp2081
The Aspen Standard peristaltic pump is triggered by the hard-wired cooling signal from the air conditioning unit. The Standard is designed to fit in ceiling voids and lift the condensate water from wall mounted machines where a gravity drain is too obtrusive.
It can also be used on cassettes fitted with an internal lift pump. The pump can be mounted remotely as it is self-priming to a height of 3 metres and will pump 6.25 litres of water per hour against a maximum head of 12 metres.
The pump runs constantly while the air conditioning system is cooling ΤΗτwhen the cooling switches off a 3 minute timer ensures that the condensate tray is emptied before the pump switches off. Rollers in the pump act as check valves to stop the condensate draining back into the condensate tray. The Standard pump is a peristaltic rotary type - which means that it is quiet in operation, very reliable and will run dry without fear of damage or embarrassing noise. The Standard does not suffer from corrosion or contamination problems.
Operates on hard-wired 150-230V cooling signal
Self-priming lifts 3 metres
12 metres discharge head
Water flow rate: 6.25 ltrs per hr @ 12 metres head
3 minute timer overrun
No siphoning back
No loud sound from dry running
Manual test switch
Pumps water, fibrously contaminated water and air
Pump rating: 0.2A, 230V AC Alternative voltages available
Fire retardant plastics
Inlet/outlet size: 6mm
Push-in plug
Wall-mounted bracket
Dimensions: 115mm(H) x 135mm(W) x 77mm(D)
Standard Peristaltic Pump By Aspen Pumps
Simply connect the Standard peristaltic pump to the appropriate drip tray (using the vinyl tube supplied), mains supply and control link to the air-conditioning units cooling signal. The pump can be mounted remotely as it is self-priming to a height of 3 metres (9.8ft) and will pump 6.25 litres (1.65 US gallons) of water per hour against a head of 12 metres (40ft).
The Standard pump is designed to run constantly while the air conditioning system is cooling.
This is achieved by linking the pump to the cooling signal. When the cooling switches off, a timer in the pump ensures that the drain tray is emptied before the pump switches off. The signal wire can be connected to the cooling signal and therefore on heating, the pump does not run.
The pump is a peristaltic rotary type - which means that it is quiet in operation, very reliable and will run dry without fear of damage or any embarrassing noise. It is not sensitive to water borne contaminants as reciprocating pumps are, and there is no mechanical water sensor to fail!
It is designed to fit in ceiling voids and lift the condensate water from wall mounted machines where a gravity drain is too obtrusive. It can be used on cassettes fitted with an internal lift pump. The rollers act as check valves to stop condensate draining back into the drip tray.
The standard pump now has a new push in plug which makes installation and maintenance easier.
Aspen Standard Service Guide
Inspect pump head regularly and change the pump head tube every 12 months or more frequently if required.
If any problems with the pump occur check the tube first!
To remove pump head make sure the roller assembly is vertical. Remove transparent cover and fit replacement pipe. The addition of a smear of silicon grease will ease the refitting of the lid, reducing potential friction noise. This only takes 3 minutes!
The test switch should always be returned to the NORMAL position after inspection.
ELECTRICAL CONNECTIONS: Brown - Permanent/Live Blue - Neutral Green/Yellow - Earth Black - Switched live from signal (110-240V)
Aspen Standard Technical Specifications
Operates on 240V cooling signal Self-priming lifts 3 metres (9.8ft) 12 metres discharge head Water flow rate: 6.25 ltrs (1.65 US gallons) per hr @ 12 metres (40ft) head 3 minute timer overrun No siphoning back No loud sound from dry running Fits into shallow ceiling void Pumps water, fibrously contaminated water and air Pump has a manual test switch Pump rating: 0.5A, 240V AC Alternative voltages available
Maximum water temperature: 40C Fire retardant plastics
Aspen Standard Installation Notes
This pump is designed to be sited upright in any position, but at all times it must have free space around the case for ventilation. Ensure that there are no kinks or trapped sections in the piping. Vinyl piping must have an ID 1/4 by OD 3/8. Fix the pipes with the tie wraps to the pump outlet and inlet.
A variable connector is provided to make easy installation between the condensate tray outlet and vinyl tube.
Product Specification Sheet
|