EcoWarrior Refrigerant Recovery Unit. FP2566
Highly affordable with no frills on the outside, itãs extremely efficient on the inside where it matters. With a 500W oil-less compressor, a large condenser and high airflow, the EcoWarrior offers a quick, easy to use solution for recovering refrigerant gases, which is not only an environmental necessity but a legal requirement. Suitable for most types of refrigerant, the unit has a liquid recovery rate of up to 80kgs/hr, a vapour recovery rate of up to 30kgs/hr, with a purge facility. Lightweight at under 13kg, the EcoWarrior has a clear display panel and a rugged, moulded case with a built-in carry handle to make your life easier.
Liquid recovery rate: up to 80kgs/hr
Vapour recovery rate: up to 30kgs/hr
Push/pull: up to 320kgs/hr
230V & 110V models available
500W oil-less compressor
High Pressure cut out of 410PSIG
Large condenser and high air flow
Suitable for most types of refrigerant, both liquid and vapour Purge facility
Rugged, moulded case
IMPORTANT NOTE: THIS EQUIPMENT MUST ONLY BE USED BY TRAINED AND COMPETENT ENGINEERS.
DIMENSIONS
Height Depth Width Weight
358mm 275mm 395mm 12.5kg
MOTOR WARNING:
The crankcase cover plate is designed for 340psig maximum pressure. Pressure above this will cause excessive deflection and leakage.
COOLING REQUIREMENTS
HEAD AND CYLINDER:
The multi-refrigerant compatible seals cannot exceed 250F without degradation. Cooling air must be directed through head and cylinder fins to prevent premature seal failures.
MOTOR:
Cooling air must be provided through the motor to maintain UL temperature rise limits of 95C.
Model Motor Rectifier (Diotec)
500CAR75 110-115V 50/60Hz DB2506P/T
Maximum exhaust pressure: 435 psig
Compression Ratio Min.: 50 (11Hg@
435psi (exhaust) and 29.5ÈÃÏ Hg barometer)
Maximum Vacuum @ open exhaust:
28.5 Hg
Refrigerants: R-11, R-12, R-22, R-113, R-114, R-123, R-134A, R-404, R-407C, R-410A, R-500, R-502.
Average service free life: 1000hrs
Ecowarrior Brochure