EDC LimpetAir Conditioning Condensate Removal Pump As air conditioners have become more and more efficient they are also getting progressively smaller. The Limpet pump does not have to be installed in the air conditioner housing but can be conveniently attached below all wall-mounted air conditioners. Maintenance is very simple. After removing the reservoir, it is simply a matter of making the pump and filter freely accessible by undoing just one screw; it can then be easily cleaned or serviced. The Limpet pump is also fitted with an electronic noise control unit. A microprocessor ensures regulated start-up and switching off of the pump which is why the pump runs extremely quietly.
-rapid, simple and uncomplicated installation below the air conditioner - simple access for rapid, effective maintenance - inconspicuous due to its aesthetic design - installed one-way valve, escapement mechanism - electronic noise control - electronic switching off of the pump by the AquaSensor - integral alarm switching and integral filter
Technical data Pump output: 12 l/h max. Conveying path distances: 15 m vertically, 60 m horizontally Water temperature: 25 ??C max. Ambient temperature range: 0 ??C to +40 ??C Thermal safety: Switches off at 80 ??C, re-starts at 35-65 ??C Spare parts and accessories Replacement filter for the drip tray Clear PVC hose (a 30 m roll) Non-return valve
|